Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: One Year
Still deciding? Get samples of US$ 40/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
3000000 RMB
Plant Area
<100 square meters
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
  • Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Find Similar Products
  • Overview
  • Product Description
  • Packaging & Shipping
  • Our factory
  • Application
  • FAQ
Overview

Basic Info.

Model NO.
customized
Ventilation Mode
Natural Ventilation
Material
ABS, PVC, PP
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Round
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Application
Refrigeration Parts
Core Components
Spray Nozzle
Sample
Be Supplied Freely
Water Flow
Cross Flow
Transport Way
by Air, by Courier, by Sea
Diameter
5mm, 28mm, 30mm, 34mm, 38mm, 40mm and etc.
Delivery Time
Within 2-4 Days
Key Selling Points
Competitive Price
Product Name
Cooling Tower Spraying Nozzle
Keyword
Cooling Tower Nozzle, Tower Spray Nozzle
Weight
as Picture
Color
Customized
OEM
Yes
Marketing Type
Ordinary Product
HS
3926901000
Transport Package
Carton, Pallets
Specification
as picture
Trademark
QINGHUI
Origin
China
HS Code
392690100
Production Capacity
3000 PCS One Day

Packaging & Delivery

Package Size
40.00cm * 35.00cm * 35.00cm
Package Gross Weight
20.000kg

Product Description

Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower NozzleXf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Product Description

Cooling tower spray nozzles are designed for optimum coverage of either the fill or coil surface. Optimum coverage increases thermal efficiency while fully wetting the surface. This in turn prevents scale build-up that will lessen the unit capacity. There are several designs for pressurized and gravity-feed systems, each fully optimized for the application. Regardless of design, nozzles are easily removed, either to accommodate new flow rates or to replace broken nozzles. To facilitate cleaning or replacement; counterflow nozzles are installed using grommets which also allows the nozzles to be properly positioned. Kits are available, complete with insert grommets for pressurized systems or installation tools for gravity systems.

Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle


Cooling Tower Spray Nozzle Working Principles

Working fluid flowing inside of the cooling tower nozzle coils, which is enwrapped by spray water on the outside. 
The heat of water is transferred by coil and become the saturated vapor when the water flow meet with the air flow.The heat is exhausted out of the cooling tower by the top fan; then the water is collected back into the bottom cooling tower basin and circulates continuously.
The spray water is cooled down via PVC radiation fin in the process of circulation, and flows the same direction with the fresh wind. The coil mainly takes sensible heat travel style. The most benefit of this style is can avoid scale formation on the outside of the coil. And this will apply especially to dealing with high temperature fluid (e.g. 60°C) or the fluid need big temperature difference (e.g. 60°C to 35°C).
 
Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Name
Cooling Tower Spray Nozzle
Color
Black, White
Size
Customized
Sample
Free Offered
Mini Order
50Pcs
Material
PP, PVC
Usage
cooling tower
Water Flow
cross flow; counter flow
Payment
T/T; western union
 


Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower NozzleFeatures and benefits of cooling tower nozzle

Secured in grommets for easy removal and replacement.
Preventing scale build-up that reduces the unit capacity.
Large orifice 360° umbrella pattern spray, eliminating dry spots.
Non-clogging design.
For all system flow rates.
For pressurized or gravity distribution system.

Caution tip
When cleaning cooling tower water mist spray nozzles do not use a screwdriver or other instrument to force debris through the cooling tower nozzle. The bottom of the nozzle is a target area that diffuses the water over the fill or coil in an umbrella type pattern. If the target area is broken, the water will pour straight onto the coil-fill surface, possibly causing damage to the fill and/or dry spots on the coil. In addition, the debris can now possibly begin to clog the fill.

Packaging & Shipping
Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle

 

Our factory

Qinghui produce all kinds of specification,style ABS nozzle,low price and fine quality,spot supplies.Cooling tower ABS nozzle,three splashed sprinkler,closed nozzle,reflection type nozzle,sewage nozzle and so on.

Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle

Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
Application

 

Xf Series Cooling Tower Spray Nozzle Water Distribution Cooling Tower Nozzle
FAQ

Q: Are you trading company or manufacturer ?
A: We are manufacturer with our own factory.

Q: How long is your delivery time?
A: Generally it is 3-5 days if the goods are in stock. Or it is 5-7 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge. And the freight cost will on the buyer's side.

Q: What is your terms of payment ?
A: Payment<=USD1000, 100% in advance. Payment>=USD1000, 30% T/T in advance ,balance before shipment.